Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22.11.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. certificate)
Remarks:
Siemens AG, Prozess-Sicherheit, Industriepark Höchst, B 596 & B 598, D-65926 Frankfurt am Main, Germany

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1 Kyobashi 1-Chome, Chuo-Ku, Tokyo 1048315, Japan/Batch No.: 130808
- Expiration date of the lot/batch: 07.08.2016
- Purity test date: 24.09.2013

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature (10-30°C)

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:no

FORM AS APPLIED IN THE TEST (if different from that of starting material): solid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10..
Executive summary:

The flammability of acylglycinate GCK-12H -T (dry matter) was investigated in a study conducted according to EU Method A.10 (Flammability (Solids)). In a preliminary test, the test item showed no reaction when a ignition source was applied for 2 minutes. Therefore the main test had not to be performed. Based on this result, the test item can be classified as a not highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10..