Registration Dossier

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
2003
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2003
Report Date:
2003

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: BS 3900 part 14
Deviations:
not specified
GLP compliance:
not specified
Type of method:
equilibrium method
Flash point apparatus:
Setaflash apparatus
Dynamic viscosity of test material:
Powder

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Flash point
Key result
Flash point:
> 104 °C
Atm. press.:
1 atm

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Running the powder through a Seta Flash Point Machine showed no flash or ignition up to 104 degrees C (the limits of the machine) and no degradation of the powder except for slight discoloration (charring) where the naked flame impinged on the surface of the powder.