Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: EU A.14 test method with GLP compliance
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Remarks:
Based on molecular structure and calculated oxygen balance
Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
The molecular structure of Setafix X 11342 does not contain any chemically unstable or highly energetic groups that might lead to an explosion and Setafix X 11342 has an oxygen balance of <-200%. Setafix X 11342 is therefore not an explosive.
Executive summary:

The molecular structure of Setafix X 11342 does not contain any chemically unstable or highly energetic groups that might lead to an explosion and Setafix X 11342 has an oxygen balance of <-200%. Setafix X 11342 is therefore not an explosive.

Description of key information

The molecular structure of Setafix X 11342 does not contain any chemically unstable or highly energetic groups that might lead to an explosion and Setafix X 11342 has an oxygen balance of <-200%. Setafix X 11342 is therefore not an explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The molecular structure of Setafix X 11342 does not contain any chemically unstable or highly energetic groups that might lead to an explosion and Setafix X 11342 has an oxygen balance of <-200%. Setafix X 11342 is therefore not an explosive.