Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
gas saturation method
Specific details on test material used for the study:
- Physical Appearance: Almost colourless to yellow-brown liquid
- Date of Expiry: 01-08-2018
- Storage Condition: Ambient (21 to 29°C)
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.006 Pa
Test no.:
#2
Temp.:
40 °C
Vapour pressure:
0.007 Pa

Method validation

- System suitability meets the acceptance criterion as the % RSD obtained was 0.87% to 4.06% which is less than 5.0%.

- Specificity meets the acceptance criterion as the interference obtained for diluent was 4.84% and for diluent spiked with trapping agent (Matrix) was 9.01% which is < 30% of the standard response at LOQ.

- Linearity meets the acceptance criterion as the correlation coefficient obtained was 1.00 which is > 0.99.

- Limit of Detection (LOD) and Limit of Quantification (LOQ): The LOD was considered at 1.60 mg/L based on S/N ≈ 3/1. The LOQ was considered at 4.00 mg/L based on S/N ≥ 10/1, where silica blank (Matrix) was used to determine the noise.

- Accuracy (% Recovery) and Precision (% RSD): Recovery meets the acceptance criterion as the % recovery obtained was 99.19% for LOQ and 100.75% for 10 LOQ which is in the range of 70 to 110 % of the nominal concentration at each fortification level. Precision meets the acceptance criterion as the % RSD obtained was1.04% for LOQ and 0.87% for 10 LOQ which is<20.0%.

- Stability meets the acceptance criterion as the % recovery obtained was 98.34% for 0 day which is in the range of 70 to 110% of the nominal concentration. Stability meets the acceptance criterion as the % recovery obtained was 104.78% for 3 days at 40ºC which is in the range of 70 to 110% of the nominal concentration.

Tests:

- Preliminary Test – Gas Saturation Method: The obtained concentrations were 30.48 mg/L at 20 mL/minute, 153.65 mg/L at 40 mL/minute and 151.10 mg/L at 60 mL/minute.

- Definitive Test – Gas Saturation Method: The mean Vapour Pressure of the test item was 6.3754 mPa at 20°C (40 mL/minute) and 6.9845 mPa at 40°C (40 mL/minute)

Description of key information

The vapour pressure of the test substance is 6.38 mPa at 20°C.

Key value for chemical safety assessment

Vapour pressure:
0.006 Pa
at the temperature of:
20 °C

Additional information