Registration Dossier

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other:
Remarks:
Eraflash

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Details on test material:
CAS 1629579-82-3
Molecular formula C18H32N2O11
EC 818-033-1

Results and discussion

Flash point
Key result
Remarks on result:
no flash point - measurement carried out until boiling temperature

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of Bis-Aminopropyl Diglycol Dimaleate.
No flash-point was observed below the temperature at which reaction and/or degradation of the test item occurred.
Executive summary:

The closed cup method was applied for the determination of the flash-point ofBis-Aminopropyl Diglycol Dimaleate.

No flash-point was observed below the temperature at which reaction and/or degradation of the test item occurred.