Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
December 29, 1992
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
1,3-benzoxazine-2,4-dione
Cas Number:
2037-95-8
IUPAC Name:
1,3-benzoxazine-2,4-dione
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Burning time:
2 s

Any other information on results incl. tables

The flame of the gas burner did ignite the test item pile. The test item melted, burned with a blue yellow flame and turned into a black residue. Grey smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The preliminary screening test was performed for the determination of the flammability of 3,4-dihydro-2,4-dioxo-1,3-2h-benzoxazine.
No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.