Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 23rd, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test substance should be considered as not highly flammable.
Executive summary:

A preliminary screening test is performed to determine if, on ignition by a gas flame, propagation by burning with flame or smouldering occurs. In this screening the substance did not ignite nor propagate combustion neither by burning with flame nor smouldering of the powder train within the four minutes test period

Conclusion

The test item should be considered as not highly flammable.