Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 1995
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
no data
Key result
Percentile:
D10
Mean:
41.21 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
D50
Mean:
139.29 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
D90
Mean:
334.47 µm
Remarks on result:
other: standard deviation not available
No.:
#1
Size:
< 10 µm
Distribution:
3.29 %
No.:
#2
Size:
< 20 µm
Distribution:
5.35 %
Conclusions:
3.29% of the particles were found to be < 10 µm
Executive summary:

The particle size distribution was determined with a laser diffraction apparatus. 3.29% of the particles analyzed were found to be < 10 µm and 5.35% < 20 µm. D10 was 41.21 µm, D50 was 139.29 µm and D90 was 334.47 µm.

Description of key information

The particle size distribution was determined with a laser diffraction apparatus. 3.29% of the particles analyzed were found to be < 10 µm and 5.35% < 20 µm. D10 was 41.21 µm, D50 was 139.29 µm and D90 was 334.47 µm.

Additional information

Source: non-GLP report