Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: In the preliminary screening test the sample was observed to burn before melting to a dark purple / red liquid. The liquid burned with a yellow / orange flame which extinguished on removal of the ignition source.
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test substance is not classified as a highly flammable solid
Executive summary:

The study was conducted according to guideline EC Test method A10. The study was conducted to determine the flammability of test substance. The results showed that in the preliminary screening test the sample was observed to burn before melting to a dark purple / red liquid. The liquid burned with a yellow / orange flame which extinguished on removal of the ignition source. These results conclude that the test substance is not classified as a highly flammable solid.

Description of key information

EU Method A.10

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test substance was not highly flammable in a study conducted according to EU Method A.10. Therefore, the test substance is not classified according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.