Registration Dossier

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Hydrolysis

The test substance hydrolysed solely into succinic acid, at the test temperature of 12 °C, in all tested buffers at pH 4, 7 and 9. The test substance was completely hydrolyzed after 48 hours, at all tested pH buffers.

Biodegradation

The test item was biodegraded by 84 % at day 28 of the closed Bottle Test. Over 60 % biodegradation was achieved within the 10-day window. Therefore, the test item is considered as readily biodegradable.