Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted for organic peroxides
Endpoint:
pyrophoric liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
self-heating substances / mixtures
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted for organic peroxides
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water

Description of key information

The substance has not to be classified as flammable gas, flammable liquid, flammable solid, flammable in contact with water, flammable aerosol, pyrophoric solid, pyrophoric liquid or self-heating substance.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammable gases

The test item is a solid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as flammable gas.

Flammable liquid

The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as flammable liquid.

Flammable solids

Test method is not applicable because according to the ECHA guidance in the application of CLP criteria, 2.8.3, organic peroxides should not be considered for classification as flammable solids since flammability is an intrinsic hazard in this class.

Pyrophoric solids

Based on the molecular structure as well as experience in in handling (contact with air for lon periods) and use shows that the substance has no pyrophoric properties. Thus, the substance does not have to be classified as pyrophoric solid.

Pyrophoric liquids

The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as pyrophoric liquid.

Substances which, in contact with water, emit flammable gases

In accordance with column 2 of REACH Annex VI and with Regulation (EC) No 1272/2008 Annex I section 2.12.4 and ECHA guidance on the application of CLP Criteria section 2.12.4.2 the classification procedure for this hazard class need not to be applied. Based on the experience in handling and use the substance does not react with water and in addition the test substance is not pyrophoric. Thus, no study was conducted and the substance was not considered for classification.

Self-heating substances and mixtures

In accordance with ECHA guidance on the Application of the CLP Criteria section 2.11.4.2 and ECHA guidance on IR/CSA chapter R.7a section R7.1.10.7 the test does not to be conducted as in general organic peroxides are not classified as self-heating substances (according to ECHA guidance on the Application of the CLP Criteria section 2.11.4.2).

Flammable Aerosols

Section 2.4.2 of Guidance on the application on the CLP Criteria state as follows: “Aerosols, this means aerosol dispensers, are any non-refillable receptacles made of metal, glass or plastics and containing a gas compressed, liquefied or dissolved under pressure, with or without a liquid, paste or powder, and fitted with a release device allowing the contents to be ejected as solid or liquid particles in suspension in a gas, as a foam, paste or powder or in a liquid state or in a gaseous state." Thus, as the substance does not meet the definition for aerosol, the test for aerosols was waived. Consequently the substance has not to be considered for classification for this hazard class.

 

In conclusion, the substance doesn't have to be considered as flammable gas, flammable liquid, flammable solid, flammable in contact with water, flammable aerosol, pyrophoric solid, pyrophoric liquid or self-heating substance.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No. 1272/2008

In accordance with Annex I Section 2.2, Section 2.3, Section 2.6, Section 2.7, Section 2.9, Section 2.10 Section 2.11, Section 2.12 of Regulation (EC) No. 1272/2008, as amended for tenth time in Regulation (EC) No. 2017/776, and UN GHS Rev 6 (2015) the test item has not to be classified as, flammable liquid, readily combustible solid in class 4 Division 4.1, self-heating substance in Class 4 Division 4.2, substances which in contact with water emit flammable gases in Class 4 Division 4.3, pyrophoric liquid, pyrophoric solid in class 4 Division 4.2, flammable gases in class 2 or as aerosol in class 2.