Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: crystalline
Specific details on test material used for the study:
Batch number: 2016110462

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Burning time:
2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Results

 

Two preliminary tests were performed and the same sample behaviour was observed.

The test item melted when the Bunsen burner flame came close, but the combustion did not propagated.

Since test item did not propagate combustion, no further testing was required.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The substance do not propagate combustion.