Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
Not specified
Specific details on test material used for the study:
Material: Solvent-free Dabco TMR-2
Color: Clear
Physical State: Liquid
Date Received: 08/11/2016
Key result
Flash point:
155.5 °C
Atm. press.:
993 mBar
Flash point:
157.5 °C
Atm. press.:
993 mBar
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flashpoint of Solvent-free Dabco TMR-2 was measured as 155.5 ± 1°C

Description of key information

The flashpoint of Solvent-free Dabco TMR-2 was measured as 155.5 ± 1°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
155.5 °C

Additional information