Registration Dossier

Administrative data

Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-06-22
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: Elatest®
Deviations:
no
Principles of method if other than guideline:
The determination of density is defined by an electronic scale and an electronic position sensor.
Each measurement starts with measuring the sample weight. Following that, the sample is put into the measuring cylinder and compressed by the piston. Thereby the piston reaches a sample-specific position, i.e. the sample is compressed to its specific volume.
For the determination of the sample volume, the difference between the piston lift is measured with empty cylinder and with filled cylinder.
The sample density is automatically determined and specified by the sample weight and the determined sample volume.
GLP compliance:
not specified
Type of method:
other: Elatest

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Density
Key result
Type:
density
Density:
1.033 g/cm³
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
Density was determined by a scientifically reasonably study, so there is no reason to conclude that the results are not reliable. Density was determined as rho (20 °C) = 1.033 g/cm³
Executive summary:

The density of (S)-(4,5-dihydro-5-thioxo-1,3,4-thiadiazol-2-yl) benzenecarbothioate was determined via Elatest as rho (20 °C) = 1.033 g/cm³.