Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Appearance/Physical state: White solid
Batch: 7061415
Purity: 99.96%
Expiry date: 13 February 2019
Storage conditions: Room temperature in the dark
Flash point:
199 °C
Atm. press.:
102 kPa
Interpretation of results:
other: not classified
Conclusions:
The flash point of the test item has been determined to be 199 ± 2 °C.
Executive summary:

The determination was carried out using a closed cup flash point tester∗, using a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008. An aliquot (2 g for temperatures up to 100 ºC and 4 g for temperatures above 100 ºC) of the test item was transferred to the sample cup of the Setaflash 30000-0 tester. The sample was heated and allowed to equilibrate at the set temperature. The test flame was introduced into the sample cup for approximately 2½ seconds by sliding the cup shutter open. Observations were made for ignition of the vapor. If no ignition occurred, the temperature was increased and the test flame re-introduced. This was repeated until the lowest reproducible temperature at which a flash occurred, using a fresh sample, was determined. The flash point of the test item has been determined to be 199 ± 2 °C at Atmospheric pressure: 102.0 kPa.

Description of key information

Key value for chemical safety assessment

Additional information