Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from the 19 december 2017 to the 16 of january 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
7 µm
Remarks on result:
other: The mean particle diameter of the particles was 7 micrometer.
Percentile:
D50
Mean:
64 µm
Remarks on result:
other: The mean particle diameter of the particles was 64 micrometer.
Percentile:
D90
Mean:
119 µm
Remarks on result:
other: The mean particle diameter of the particles was 119 micrometer.

The particle size of the sample is in the range between 0.4 and 450 μm.

Conclusions:
The particle size distribution of test item was determined following ISO 13320 (Particle size analysis - Laser diffraction methods).

The median particle size D50 of the test item deduced from the particle size distributions was : 64 micrometer.
The particle size D10 of the test item deduced from the particle size distributions was : 7 micrometer.
The particle size D90 of the test item deduced from the particle size distributions was : 119 micrometer.

Description of key information

The particle size distribution of test item was determined following ISO 13320 (Particle size analysis - Laser diffraction methods).

The median particle size D50 of the test item deduced from the particle size distributions was: 64 micrometer.

The particle size D10 of the test item deduced from the particle size distributions was: 7 micrometer.

The particle size D90 of the test item deduced from the particle size distributions was: 119 micrometer.

Additional information