Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
August 24, 2009
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
March 23, 2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Version / remarks:
August 1996
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
3,4,5-trimethoxycinnamic acid
EC Number:
201-999-8
EC Name:
3,4,5-trimethoxycinnamic acid
Cas Number:
90-50-6
Molecular formula:
C12H14O5
IUPAC Name:
3-(3,4,5-trimethoxyphenyl)acrylic acid
Test material form:
solid: crystalline
Remarks:
light yellow
Details on test material:
CH03216 / E1A

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0 Pa
Temp.:
25 °C
Vapour pressure:
0 Pa

Applicant's summary and conclusion

Conclusions:
The isothermal TGA effusion method was applied for the determination of the vapour pressure of 3,4,5-TRIMETHOXYCINNAMIC ACID.
The vapour pressure of the test item at 20°C (293K) and 25°C (298K) was 1.1E-06 and 2.7E-06 Pa, respectively.