Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 February 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2003
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094 (Flash Point by Modified Continuosly Closed Cup (MCCCFP) Tester)
Version / remarks:
2004
Deviations:
no
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
165.5 °C
Atm. press.:
99.32 kPa

Table 1. Flash point results

 Replicate number  Flash point (°C)  Atmospheric pressure (kPa)  Corrected flash point (°C)
 1  165.0  99.32  165.5
 2  165.0  99.32  165.5
 3  165.0  99.32  165.5
     Mean value (n=3)  165.5
     SD (n=3)  0.00
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point was determined to be 165.5°C with a continuously closed cup flash point tester.
Executive summary:

The flash point of the test item was determined by continuously closed cup flash point tester to be 165.5°C. This study is reliable without restriction (Klimisch 1) as it was performed according to guidelines EU A.9, OPPTS 830.6315, ISO 2719 and ASTM D7094. The study was not GLP-compliant, however the test facility is GLP-compliant.

Description of key information

The flash point of the test item was determined by continuously closed cup flash point tester to be 165.5 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
165.5 °C

Additional information

This study is reliable without restriction (Klimisch 1) as it was performed according to guidelines EU A.9, OPPTS 830.6315, ISO 2719 and ASTM D7094 (2017). The study was not GLP-compliant, however the test facility is GLP-compliant. With a measured flash point > 60°C, the test item does not have to be classified as flammable liquid according to GHS or CLP Regulation EC 1272/2008 Annex 1.