Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 9th, 2014 to January 22nd, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
other: Rapid Tester NPV 310 of the company Normalab

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Specific details on test material used for the study:
Test material name (as stated in the report): Cetonal
Batch No.: SC00011028
Expiry date: 23 June, 2016

Results and discussion

Flash point
Key result
Flash point:
97.5 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item Cetonal has a flash point of 97.5 °C, according to Regulation EC No. 440/2008 Method A.9. Flash Point.
Executive summary:

The test item Cetonal has a flash point of 97.5 °C, according to Regulation EC No. 440/2008 Method A.9. Flash Point.