Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-12-12 to 2016-12-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Version / remarks:
Adopted 27 July 1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Version / remarks:
August 1996
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
photocell detection
Specific details on test material used for the study:
- Lot: 216-106
- Expiry date: 2018-06-16
- Storage conditions: Keep at room temperature
Key result
Decomposition:
yes
Decomp. temp.:
> 212 - <= 375 °C
Remarks on result:
not determinable
Remarks:
The test substance started to decomposed directly after melting. No boiling was observed up to 375 °C.
Conclusions:
The test substance started to decompose directly after melting. No boiling was observed up to 375 °C.
Executive summary:

The boiling point of the test substance was determined using a method following Siwoloboff with automatic photo-electrical detection according to OECD 103. Three preliminary tests were performed. In these tests no boiling point was observed from melting point (212 °C) up to 375 °C. After the test item melted in the sample tube it began to darken immediately. At the end of each measurement the samples were hardened, their colors darkened and moved to the upper part of the capillary. After the samples cooled to room temperature the appearance of the samples remained above-mentioned, the changes were irreversible. As no boiling point was detected in the preliminary test, the main test was not performed. Boiling point was not observed from melting point up to 375 °C. Based on the visual observations in the preliminary tests the changes of appearance of the test item were irreversible. Therefore it was concluded that the test item started to decompose after melting.

Description of key information

The test substance started to decompose directly after melting. No boiling was observed up to 375 °C.

Key value for chemical safety assessment

Additional information

The boiling point of the test substance was determined using a method following Siwoloboff with automatic photo-electrical detection according to OECD 103. Three preliminary tests were performed. In these tests no boiling point was observed from melting point (212 °C) up to 375 °C. After the test item melted in the sample tube it began to darken immediately. At the end of each measurement the samples were hardened, their colors darkened and moved to the upper part of the capillary. After the samples cooled to room temperature the appearance of the samples remained above-mentioned, the changes were irreversible. As no boiling point was detected in the preliminary test, the main test was not performed. Boiling point was not observed from melting point up to 375 °C. Based on the visual observations in the preliminary tests the changes of appearance of the test item were irreversible. Therefore it was concluded that the test item started to decompose after melting.