Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26 August - 22 December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
Qualifier:
according to
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Deviations:
no
GLP compliance:
yes
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study reports): JNJ-150098-AAC (T001310)
- Physical state: solid
- Appearance white powder
Specific details on test material used for the study:
- Batch n°: I14KB4913
- Analytical purity: 97.4% (base titration)
- Expiration date: 23 November 2020 (retest date)
- Storage condition: at room temperature

Results and discussion

Boiling point
Key result
Atm. press.:
1 013.25 hPa
Decomposition:
yes
Remarks:
Boiling of the test item was not observed below the temperature of decomposition and/or reaction, therefore the test item has no boiling temperature.
Remarks on result:
not determinable

Any other information on results incl. tables

Boiling of the test item was not observed below the temperature of decomposition and/or reaction.

Reaction and/or decomposition of the test item was observed directly after melting. Based on this, the test item has no boiling temperature.

Applicant's summary and conclusion

Conclusions:
The test item T001310 has no boiling temperature (reaction/decomposition observed before boiling).