Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Carbamic acid, N-[3-(tiethoxysilyl) propyl]-, 2-[ethyl(4-nitrosophenyl)amino]ethyl ester
Cas Number:
1195231-94-7
Molecular formula:
C20 H35 N3 O6 Si
IUPAC Name:
Carbamic acid, N-[3-(tiethoxysilyl) propyl]-, 2-[ethyl(4-nitrosophenyl)amino]ethyl ester
Constituent 2
Reference substance name:
[SPEC][/SPEC][SYN][/SYN][AM][/AM]
IUPAC Name:
[SPEC][/SPEC][SYN][/SYN][AM][/AM]
Constituent 3
Reference substance name:
[CS]000000419807[/CS]
IUPAC Name:
[CS]000000419807[/CS]

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
0.9 other: mm/s (migrated information)
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
1.1 other: mm/s (migrated information)

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
Since the burning rate of the test item was significantly smaller the burning rate of the reference material, the test item has no oxiziding properties.