Irritation studies are technically not feasible because the substance is a gas at standard temperature and pressure. However no signs of eye, skin, or respiratory irritation were observed in several whole-body and nose-only inhalation toxicity studies. Therefore, no classification is required for skin or eye irritation according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.