Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The major part of the test item has got a size situated between 100 μm and 1 mm with 51.4% of the test item. 39.1% of the test item has got a size situated below 100 μm.

Additional information

The size distribution was performed according to OECD Guideline 110 and GLP. No deviation from the guidelines was observed during the test.