Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: pale yellow liquid
Details on test material:
Batch VE00402514
Purity 97.3%
Expiry date June 20, 2016

Results and discussion

Flash point
Flash point:
74 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
The falsh point of the Decenal-4-trans was determined by the Pensky-Martens method according to the ISO 2719. The result is: 74.0°C