Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Key value for chemical safety assessment

Genetic toxicity in vitro

Description of key information

Ames test: Under the conditions of the study, it is concluded that the test material is mutagenic in the Salmonella typhimurium reverse mutation assay in the presence of metabolic activation and not mutagenic in the Escherichia coli reverse mutation assay.

Link to relevant study records
Reference
Endpoint:
in vitro gene mutation study in bacteria
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 July 2016 to 27 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 471 (Bacterial Reverse Mutation Assay)
Version / remarks:
1997
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.13/14 (Mutagenicity - Reverse Mutation Test Using Bacteria)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes
Type of assay:
bacterial forward mutation assay
Specific details on test material used for the study:
A correction factor of 1.031 was used to correct for the purity.
Target gene:
- Histidine requirement in the Salmonella typhimurium strains (Histidine operon).
- Tryptophan requirement in the Escherichia coli strain (Tryptophan operon).
Species / strain / cell type:
S. typhimurium TA 1535, TA 1537, TA 98 and TA 100
Details on mammalian cell type (if applicable):
- Type and identity of media: Samples of frozen stock cultures of bacteria were transferred into enriched nutrient broth (Oxoid LTD, Hampshire, England) and incubated in a shaking incubator (37 ± 1 °C, 150 rpm), until the cultures reached an optical density of 1.0 ± 0.1 at 700 nm (10^9 cells/mL). Freshly grown cultures of each strain were used for testing.
- Properly maintained: Yes. The Salmonella typhimurium strains are regularly checked to confirm their histidine requirement, crystal violet sensitivity, ampicillin resistance (TA98 and TA100), UV sensitivity and the number of spontaneous revertants. Stock cultures of the strains were stored in liquid nitrogen (-196 °C).
Species / strain / cell type:
E. coli WP2 uvr A
Details on mammalian cell type (if applicable):
- Type and identity of media: Samples of frozen stock cultures of bacteria were transferred into enriched nutrient broth (Oxoid LTD, Hampshire, England) and incubated in a shaking incubator (37 ± 1 °C, 150 rpm), until the cultures reached an optical density of 1.0 ± 0.1 at 700 nm (10^9 cells/mL). Freshly grown cultures of each strain were used for testing.
- Properly maintained: Yes. The strain is regularly checked to confirm the tryptophan requirement, UV-sensitivity and the number of spontaneous revertants. Stock cultures were stored in liquid nitrogen (-196 °C).
Metabolic activation:
with and without
Metabolic activation system:
S9-mix (rat liver S9-mix induced by Aroclor 1254)
Test concentrations with justification for top dose:
- Dose range finding study (TA100 and WP2uvrA only): 1.7, 5.4, 17, 52, 164, 512, 1600 and 5000 μg/plate (absence and presence of S9-mix)
- Mutation experiment (TA1535, TA1537 and TA98): 17, 52, 164, 512, 1600 and 5000 μg/plate (absence and presence of S9-mix)
Vehicle / solvent:
- Vehicle(s)/solvent(s) used: Dimethyl sulfoxide (DMSO)
- Justification for choice of solvent/vehicle: Chosen following a solubility test. At a concentration of 50 mg/mL, the test material formed a suspension in dimethyl sulfoxide whereas at 16 mg/mL and lower it was fully soluble. The stock solution was treated with ultrasonic waves to obtain a homogeneous suspension.
Untreated negative controls:
no
Negative solvent / vehicle controls:
yes
Remarks:
DMSO
True negative controls:
no
Positive controls:
yes
Positive control substance:
4-nitroquinoline-N-oxide
2-nitrofluorene
sodium azide
methylmethanesulfonate
other: ICR-191, 2-aminoanthracene
Details on test system and experimental conditions:
METHOD OF APPLICATION: in agar (plate incorporation)

DOSE RANGE FINDING TEST/ MUTATION ASSAY
Selection of an adequate range of doses was based on a dose range finding test with the strains TA100 and WP2uvrA, both with and without S9-mix and reported as part of the first mutation experiment.

MUTATION ASSAY
At least five different doses (increasing with approximately half-log steps) of the test material were tested in each strain both in the absence and presence of 5 % (v/v) S9-mix in the tester strains TA1535, TA1537 and TA98.

Top agar in top agar tubes was melted by heating to 45 ± 2 °C. The following solutions were successively added to 3 mL molten top agar: 0.1 mL of a fresh bacterial culture (10^9 cells/mL) of one of the tester strains, 0.1 mL of a dilution of the test material in DMSO and either 0.5 mL S9-mix (in case of activation assays) or 0.5 mL 0.1 M phosphate buffer (in case of non-activation assays). The ingredients were mixed on a Vortex and the content of the top agar tube was poured onto a selective agar plate. After solidification of the top agar, the plates were inverted and incubated in the dark at 37.0 ± 1.0 °C for 48 ± 4 h. After this period revertant colonies (histidine independent (His+) for Salmonella typhimurium bacteria and tryptophan independent (Trp+) for Escherichia coli) were counted.

NUMBER OF REPLICATIONS: Testing was performed in triplicate

COLONY COUNTING
The revertant colonies were counted automatically with the Sorcerer Colony Counter. Plates with sufficient test material precipitate to interfere with automated colony counting were counted manually. Evidence of test material precipitate on the plates and the condition of the bacterial background lawn were evaluated when considered necessary, macroscopically and/or microscopically by using a dissecting microscope.

DETERMINATION OF CYTOTOXICITY
- Method: To determine the toxicity of the test material, the reduction of the bacterial background lawn, the increase in the size of the microcolonies and the reduction of the revertant colonies were examined.
Evaluation criteria:
ACCEPTABILITY OF THE ASSAY
The assay is considered acceptable if it meets the following criteria:
a) The vehicle control and positive control plates from each tester strain (with or without S9-mix) must exhibit a characteristic number of revertant colonies when compared against relevant historical control data generated at the testing facility.
b) The selected dose range should include a clearly toxic concentration or should exhibit limited solubility as demonstrated by the preliminary toxicity range-finding test or should extend to 5 mg/plate.
c) No more than 5 % of the plates are lost through contamination or some other unforeseen event. If the results are considered invalid due to contamination, the experiment will be repeated.

DATA EVALUATION
In addition to the criteria stated below, any increase in the total number of revertants should be evaluated for its biological relevance including a comparison of the results with the historical control data range.
A test material is considered negative (not mutagenic) in the test if:
a) The total number of revertants in the tester strain TA100 or WP2uvrA is not greater than two (2) times the concurrent control, and the total number of revertants in tester strains TA1535, TA1537 or TA98 is not greater than three (3) times the concurrent vehicle control.
b) The negative response should be reproducible in at least one follow-up experiment.
A test material is considered positive (mutagenic) in the test if:
a) The total number of revertants in the tester strain TA100 or WP2uvrA is greater than two (2) times the concurrent control, or the total number of revertants in tester strains TA1535, TA1537, TA98 is greater than three (3) times the concurrent vehicle control.
b) In case a follow up experiment is performed when a positive response is observed in one of the tester strains, the positive response should be reproducible in at least one follow up experiment.
Statistics:
No formal hypothesis testing was done..
Key result
Species / strain:
S. typhimurium, other: TA1537, TA98 and TA100
Metabolic activation:
with
Genotoxicity:
positive
Cytotoxicity / choice of top concentrations:
no cytotoxicity, but tested up to precipitating concentrations
Vehicle controls validity:
valid
Untreated negative controls validity:
not applicable
Positive controls validity:
valid
Key result
Species / strain:
S. typhimurium, other: TA1537, TA98 and TA100
Metabolic activation:
without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
cytotoxicity
Remarks:
only observed in tester strain TA100 in the absence of S9-mix at concentrations of 512 μg/plate and upwards.
Vehicle controls validity:
valid
Untreated negative controls validity:
not applicable
Positive controls validity:
valid
Key result
Species / strain:
S. typhimurium TA 1535
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
no cytotoxicity, but tested up to precipitating concentrations
Vehicle controls validity:
valid
Untreated negative controls validity:
not applicable
Positive controls validity:
valid
Key result
Species / strain:
E. coli WP2 uvr A
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
no cytotoxicity, but tested up to precipitating concentrations
Vehicle controls validity:
valid
Untreated negative controls validity:
not applicable
Positive controls validity:
valid
Additional information on results:
DOSE RANGE FINDING TEST/MUTATION EXPERIMENT
- Precipitate: in the dose range finding test, precipitation of the test material was observed at the start of the incubation period at concentrations of 512 μg/plate and upwards. At the end of the incubation period the test material precipitated on the plates at dose levels of 512 μg/plate and upwards in the absence of S9-mix and at 5000 μg/plate in the presence of S9-mix. In the first mutation experiment, precipitation of the test material on the plates was observed at the start of the incubation period at the concentration of 5000 μg/plate and at 1600 and 5000 μg/plate at the end of the incubation period.
- Toxicity: Since the test material precipitated heavily on the plates at the test substance concentration of 5000 μg/plate in tester strain TA100 (presence of S9-mix), the number of revertants at this dose level could not be determined. Cytotoxicity, as evidenced by a decrease in the number of revertants was only observed in tester strain TA100 in the absence of S9-mix at concentrations of 512 μg/plate and upwards. There was no reduction in the bacterial background lawn and no biologically relevant decrease in the number of revertants at any of the concentrations tested in all other tester strains in the absence and presence of S9-mix.
- Mutagenicity: No increases in the number of revertants were observed upon treatment with the test material in the absence of S9-mix.
The test material induced increases in the number of revertant colonies in the presence of S9-mix. The increases were observed in tester strain TA100 (up to 4.1-fold), in tester strain TA1537 (up to 37-fold) and in tester strain TA98 (up to 51-fold).
The test material did not induce a significant dose-related increase in the number of revertant colonies in tester strains TA1535 and WP2uvrA in the presence of S9-mix.

DISCUSSION
No increases in the number of revertants were observed upon treatment with the test material in the absence of S9-mix. In the presence of S9-mix, the test material did not induce a significant dose-related increase in the number of revertant colonies in the tester strains TA1535 and WP2uvrA. The test material induced dose related increases in three tester strains (TA1537, TA98 and TA100). The increases observed in the three tester strains were above the laboratory historical control data range, dose-related and were up to 37, 31 and 4.0-fold the concurrent controls, respectively. These increases are considered to be biologically relevant and the test material is considered to be mutagenic.
The negative and strain-specific positive control values were within the laboratory historical control data ranges indicating that the test conditions were adequate and that the metabolic activation system functioned properly.

Table 1: Dose Range-finder and Mutation Experiment

+/- S9 Mix

Concentration (µg/plate)

Mean number of colonies/plate (3 replicates)

Base-pair Substitution Type

Frameshift Type

TA100

TA1535

WP2uvrA

TA98

TA1537

-

PC

DMSO

1.7

5.4

17

52

164

512

1600

5000

833

86

84

72

82

76

78 NP

56 SP

36 SP

56 n MP

803

10

-

-

7

7

8

16 NP

11 SP

6 n MP

1208

21

26

32

30

26

28 NP

38 SP

32 SP

12 n MP

1302

9

-

-

14

11

15

15 NP

16 SP

13 n MP

1219

5

-

-

6

8

8

11 NP

13 SP

7 n MP

+

PC

DMSO

1.7

5.4

17

52

164

512

1600

5000

1184

99

98

98

129

168

261

404

214 NP

n HP

167

14

-

-

9

11

9

21 NP

12 SP

7 n MP

411

40

40

42

51

39

42

43

33 NP

19 n MP

1119

14

-

-

83

184

387

712 NP

431 SP

211 n MP

283

5

-

-

16

31

70

144 NP

184 SP

80 n MP

HP= Heavy Precipitate; the number of revertant colonies could not be determined

MP = Moderate Precipitate

NP = No precipitate

SP = Slight Precipitate

n = Normal bacterial background lawn

Conclusions:
Under the conditions of the study, it is concluded that the test material is mutagenic in the Salmonella typhimurium reverse mutation assay in the presence of metabolic activation and not mutagenic in the Escherichia coli reverse mutation assay.
Executive summary:

The potential of the test material to cause mutagenic effects in bacteria was assessed in accordance with the standardised guidelines OECD 471 and EU Method B.13/14 under GLP conditions.

The test material was tested in the Salmonella typhimurium reverse mutation assay with four histidine-requiring strains of Salmonella typhimurium (TA1535, TA1537, TA98 and TA100) and in the Escherichia coli reverse mutation assay with a tryptophan-requiring strain of Escherichia coli (WP2uvrA). The test was performed in the presence and absence of S9-mix (rat liver S9-mix induced by Aroclor 1254).

In the dose range finding test, the test material was tested up to concentrations of 5000 μg/plate in the absence and presence of S9-mix in the strains TA100 and WP2uvrA. The test material precipitated on the plates at dose levels of 512 μg/plate and upwards in the absence of S9-mix and at 5000 μg/plate in the presence of S9-mix. Since the test material precipitated heavily on the plates at the test material concentration of 5000 μg/plate in tester strain TA100 (presence of S9-mix), the number of revertants at this dose level could not be determined. Cytotoxicity, as evidenced by a decrease in the number of revertants, was observed in tester strain TA100 in the absence of S9-mix at the concentrations of 512 μg/plate and upwards. Results of this dose range finding test were reported as part of the first mutation assay.

Based on the results of the dose range finding test, the test material was tested in the mutation assay at a concentration range of 17 to 5000 µg/plate in the absence and presence of S9-mix in the tester strains TA1535, TA1537 and TA98. The test material precipitated on the plates at dose levels of 1600 and 5000 μg/plate. The bacterial background lawn was not reduced at any of the concentrations tested and no biologically relevant decrease in the number of revertants was observed.

No increases in the number of revertants were observed upon treatment with the test material in the absence of S9-mix.

In the presence of S9-mix, the test material did not induce a significant dose-related increase in the number of revertant colonies in the tester strains TA1535 and WP2uvrA. The test material induced dose related increases in three tester strains (TA1537, TA98 and TA100). The increases observed in these three tester strains were above the laboratory historical control data range, dose-related and were up to 37, 31 and 4.0-fold the concurrent controls, respectively. These increases are considered to be biologically relevant and the test material is considered to be mutagenic.

The negative and strain-specific positive control values were within the laboratory historical control data ranges indicating that the test conditions were adequate and that the metabolic activation system functioned properly.

Under the conditions of the study, it is concluded that the test material is mutagenic in the Salmonella typhimurium reverse mutation assay in the presence of metabolic activation and not mutagenic in the Escherichia coli reverse mutation assay.

Endpoint conclusion
Endpoint conclusion:
adverse effect observed (positive)

Genetic toxicity in vivo

Endpoint conclusion
Endpoint conclusion:
no study available

Additional information

The potential of the test material to cause mutagenic effects in bacteria was assessed in accordance with the standardised guidelines OECD 471 and EU Method B.13/14 under GLP conditions. The study was assigned a reliability score of 1 in accordance with the criteria for assessing data quality set forth by Klimisch et al. (1997).

The test material was tested in the Salmonella typhimurium reverse mutation assay with four histidine-requiring strains of Salmonella typhimurium (TA1535, TA1537, TA98 and TA100) and in the Escherichia coli reverse mutation assay with a tryptophan-requiring strain of Escherichia coli (WP2uvrA). The test was performed in the presence and absence of S9-mix (rat liver S9-mix induced by Aroclor 1254).

In the dose range finding test, the test material was tested up to concentrations of 5000 μg/plate in the absence and presence of S9-mix in the strains TA100 and WP2uvrA. The test material precipitated on the plates at dose levels of 512 μg/plate and upwards in the absence of S9-mix and at 5000 μg/plate in the presence of S9-mix. Since the test material precipitated heavily on the plates at the test material concentration of 5000 μg/plate in tester strain TA100 (presence of S9-mix), the number of revertants at this dose level could not be determined. Cytotoxicity, as evidenced by a decrease in the number of revertants, was observed in tester strain TA100 in the absence of S9-mix at the concentrations of 512 μg/plate and upwards. Results of this dose range finding test were reported as part of the first mutation assay.

Based on the results of the dose range finding test, the test material was tested in the mutation assay at a concentration range of 17 to 5000 µg/plate in the absence and presence of S9-mix in the tester strains TA1535, TA1537 and TA98. The test material precipitated on the plates at dose levels of 1600 and 5000 μg/plate. The bacterial background lawn was not reduced at any of the concentrations tested and no biologically relevant decrease in the number of revertants was observed.

No increases in the number of revertants were observed upon treatment with the test material in the absence of S9-mix.

In the presence of S9-mix, the test material did not induce a significant dose-related increase in the number of revertant colonies in the tester strains TA1535 and WP2uvrA. The test material induced dose related increases in three tester strains (TA1537, TA98 and TA100). The increases observed in these three tester strains were above the laboratory historical control data range, dose-related and were up to 37, 31 and 4.0-fold the concurrent controls, respectively. These increases are considered to be biologically relevant and the test material is considered to be mutagenic.

The negative and strain-specific positive control values were within the laboratory historical control data ranges indicating that the test conditions were adequate and that the metabolic activation system functioned properly.

Under the conditions of the study, it is concluded that the test material is mutagenic in the Salmonella typhimurium reverse mutation assay in the presence of metabolic activation and not mutagenic in the Escherichia coli reverse mutation assay.

Given that there were some positive responses in the assay, this must be borne in mind when selecting the appropriate studies to further investigate the genotoxic potential of the test material at the next tonnage level. Based on the results of this single in vitro study in bacteria, at this stage it is not considered appropriate to classify the material.

Justification for classification or non-classification

In accordance with the criteria for classification as defined in Annex I, Regulation (EC) No 1272/2008, the substance does not require classification with respect to genetic toxicity.