Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Type of information:
migrated information: read-across based on grouping of substances (category approach)
Adequacy of study:
key study
Study period:
1/2010-5/2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to ASTM method D6450-99

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Principles of method if other than guideline:
The flammability of the liquid test substance is given by its flash point. The flash point was determined in a study according to test method ASTM D6450-99, see section 4.11.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Decyldimethylamine
EC Number:
214-302-7
EC Name:
Decyldimethylamine
Cas Number:
1120-24-7
Molecular formula:
C12H27N
IUPAC Name:
N,N-dimethyldecan-1-amine

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

In a study according to test method ASTM D6450 -99, the flash point was determined to be 91°C (see section 4.11), which is considerably higher than the criteria for classification as a flammable liquid (<=60°C according to CLP Regulation and <=55°C according to Directive 67/548/EEC).

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information according to EU criteria
Conclusions:
The test substance has a flash point of 91°C and is non flammable.
Executive summary:

The flammability of the test substance is given by its flash point. The test substance has a flash point of 91°C°C in a test according to ASTM method D6450 -99 and is non flammable according to EU criteria.