Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 July 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to
Guideline:
other: Not stated
Principles of method if other than guideline:
Viscosity of benzyl acetate was measured using a Brookfield Viscometer. The measurement was performed at 25 °C
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Standard covering the apparatus used:
Instrument /Model: Brookfield/LVT
Spindle: LV1
Speed: 60 rpm
Key result
Temp.:
other: 25.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4.5

No further details were provided

Conclusions:
The viscosity of benzyl acetate was measured to be 4.5 mPa s at 25 °C using a Brookfield Viscometer
Executive summary:

The viscosity of benzyl acetate was measured to be 4.5 mPa s at 25 °C using a Brookfield Viscometer

Description of key information

The viscosity of benzyl acetate was measured to be 4.5 mPa s at 25 °C using a Brookfield Viscometer

Key value for chemical safety assessment

Viscosity:
4.5 mPa · s (dynamic)
at the temperature of:
25 °C

Additional information