Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well conducted study according to OECD guideline under Internal management system, certificate of analysis included in the report.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
Adopted May 12, 1981
Deviations:
no
GLP compliance:
no
Remarks:
Internal management system
Type of method:
rotational viscometer (dynamic)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
7.5

The rheometer was calibrated at 13-12-2011.
A calibration check was performed prior to the measurement . The estimated accuracy is ± 1%.

Viscosity measurement of the REACH test substance, batch no. 0904130207

di-tert-butyl peroxideat 20°C (duplicate)

12 RPM

0.84 mPa.s

0.84 mPa.s

30 RPM

0.83 mPa.s

0.83 mPa.s

60RPM

0.82 mPa.s

0.84mPa.s

As there was no effect due to shear rate, the average viscosity value can be set at 0.83 mPa.s at 30 rpm (20°C).

Conclusions:
The viscosity of di-tert-butyl peroxide is 0.83 mPas at 30 rpm (20°C).
Executive summary:

The viscosity of di-tert-butyl peroxide(CAS 110-05-4)was determined accordingto OECD Guideline 114 , and in accordance with European Chemicals Agency (ECHA), Guidance on information requirements and chemical safety assessment, Chapter R.7a, Endpoint specific guidance, May 2008.

 

The viscosity of the test substance is:

 

di-tert-butyl peroxideat 20°C (duplicate)

12 RPM

0.84 mPa.s

0.84 mPa.s

30 RPM

0.83 mPa.s

0.83 mPa.s

60RPM

0.82 mPa.s

0.84mPa.s

Description of key information

The viscosity of di-tert-butyl peroxide is 0.83 mPas at 30 rpm (20°C).

Key value for chemical safety assessment

Viscosity:
0.83 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information