Registration Dossier

Administrative data

Endpoint:
other distribution data
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Preliminary test Value is suitable for orientation of volatility.

Data source

Reference
Title:
No information
Author:
Röhm GmbH: Bestimmung der Wasserlöslichkeit und Hydrolyse|(1998)
Year:
1998

Materials and methods

Type of study:
volatility
Media:
water - air

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Any other information on results incl. tables

Results:
2.5 % volatized after 24 hours.
After 24 hours (open system, after volatization and hydrolysis) 91.5 % of the test substance remained in the test vessel.

Applicant's summary and conclusion