Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007-11-07 - 2008-05-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Non-GLP. Study performed and documented equivalent to GLP standards. Study according to relevant guideline.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Directive 92/69/EEC, Official Journal L 383 A 1992, Pensky-Martens method, ASTM D93
GLP compliance:
no
Remarks:
Study performed and documented equivalent to GLP standards.
Type of method:
closed cup
Key result
Flash point:
114 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
In a valid guideline study the flash point is reported to be 114 °C at 1013 hPa (Pensky Martens closed cup).
Executive summary:

In a valid guideline study the flash point is reported to be 114 °C at 1013 hPa (Pensky Martens closed cup).

NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.

Description of key information

FP: 114 °C (closed cup method, ASDM D 93, EU A9), Evonik Röhm GmbH (2008)
    
    

), Evonik Röhm GmbH (2008)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
114 °C

Additional information

FP: 114 °C (closed cup method), Evonik Röhm GmbH (2008)