Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study according to EU/OECD guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
other: dynamic method + vapor pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0.002 hPa
Temp.:
26.8 °C
Vapour pressure:
0.018 hPa
Temp.:
132.2 °C
Vapour pressure:
25.2 hPa

Applicant's summary and conclusion