Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
Vinylene carbonate
EC Number:
212-825-5
EC Name:
Vinylene carbonate
Cas Number:
872-36-6
Molecular formula:
C3H2O3
IUPAC Name:
2H-1,3-dioxol-2-one
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material:
N210814013
- Purity, including information on contaminants, isomers, etc.: >=99.9%

Results and discussion

Viscosity
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.306

Applicant's summary and conclusion

Conclusions:
The test was conducted according to ISO 3104 Petroleum products-transparent and opaque liquids-determination of kinematic viscosity. The kinematic viscosity of the sample is 1.306 mm²/s at 20.0℃.