Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Principles of method if other than guideline:
the method used is implemented in SEPPIC sa lab and use the following tool:STAMPF STAV 2003.The density is calculated from the difference in weight between the full and empty pycnometer and its known volume.
GLP compliance:
no
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Montanov 202
- Substance type: UVCB
- Physical state: Solid
- Analytical purity: >99%

Results and discussion

Density
Type:
relative density
Density:
ca. 870 kg/m³
Temp.:
25 °C

Applicant's summary and conclusion

Conclusions:
the relative density of the test item is 870 kg/M3
Executive summary:

the relative density of the test item is 870 kg/M3.The test was performed in SEPPIC SA analytical laboratory following our Internal guideline/method.