Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From August 2011 to 7 September 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test method is according to OECD guideline 109. No GLP.
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
no
Type of method:
pycnometer method
Type:
relative density
Density:
1.048
Temp.:
20 °C
Conclusions:
The mean relative density (20/4) of the test substance was determined by average of three replicates: 1.0477 ± 0.0001.
Executive summary:

The objective of the study was to determined the relative density of the test substance according to OECD guideline 109 (pyknometer method). The mean relative density (20/4) of the test substance was determined by average of three replicates: 1.0477 ± 0.0001.

Description of key information

Key study: OECD guideline 109. No GLP. 

Key value for chemical safety assessment

Relative density at 20C:
1.048

Additional information

Key study: OECD guideline 109. The mean relative density (20/4) of the product was determined by average of three

replicates: 1.0477 ± 0.0001