Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From August 2011 to 7 September 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test method is according to OECD guideline 103. No GLP.
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Boiling pt.:
> 300 °C
Remarks on result:
other: Atmospheric pressure
Conclusions:
The boiling point pf the test material was determined to be > 300 ºC.
Executive summary:

The boiling point was determined according to OECD guideline 103. The boiling point of the test material was determined to be > 300 ºC.

Description of key information

Key study: Test method is according to OECD guideline 103. No GLP. 

Key value for chemical safety assessment

Additional information

Key study: Test method is according to OECD guideline 103. The boiling point of the test material was determined to be > 300 ºC.