Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 January - 22 February 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
3-bromo-5-fluoro-1-(4-methylbenzenesulfonyl)-1H-pyrrolo[2,3-b]pyridine
Cas Number:
1417421-99-8
Molecular formula:
C14H10BrFN2O2S
IUPAC Name:
3-bromo-5-fluoro-1-(4-methylbenzenesulfonyl)-1H-pyrrolo[2,3-b]pyridine
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
- Batch n°: I15ID3592
- Analytical purity: 99.3%
- Expiration date: 21 September 2017
- Storage condition: at room temperature

Results and discussion

Relative self-ignition temperature (solids)
Key result
Remarks on result:
no self-ignition observed up to the melting point

Any other information on results incl. tables

No spontaneous ignition occured and no significant exothermic effect of the test item was observed. It showed that the test item is not a self-heating substance. According to the UN guideline, no further testing is required.

After the experiment, the test item had turned into a beige/brown to dark brown residue and was partially collected in a container that was placed below the cube. It indicated that the test item had molten, decomposed and/or reacted during the experiment.

Applicant's summary and conclusion

Conclusions:
Based on the results of the EC A.16 test performed, the test item is considered not a self-heating substance.