Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The study does not need to be conducted because the substance is a liquid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item is a liquid and, in line with ECHA Guidance on Information Requirements and Chemical Safety Assessment Chapter R.7a: Endpoint specific guidance (Version 6.0; July 2017), relevant properties for classification of the substance as flammable are the determined flash point and boiling point. Further experimental investigation of flammability is therefore not required.

Justification for classification or non-classification

Flammability of the test material has been investigated via determination of flashpoint (95.1 ± 1 °C using the Pensky-Martens closed cup method). Therefore, in accordance with CLP Regulation (EC) No 1272/2008, the substance is not classified as flammable.