Administrative data

First-aid measures

General advice : Move out of dangerous area. Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled : Move to fresh air. Consult a physician after significant exposure
In case of skin contact : Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty.
In case of eye contact : Small amounts splashed into eyes can cause irreversible tissue damage and blindness. In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing.
If swallowed : Clean mouth with water and drink afterwards plenty of water. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. Take victim immediately to hospital.

Most important symptoms and effects, both acute and delayed:
Symptoms : Aspiration may cause pulmonary oedema and pneumonitis. Corrosive effects. Dizziness. Drowsiness. Toxic effects for reproduction

Indication of any immediate medical attention and special treatment needed: Treatment : For specialist advice physicians should contact the Poisons Information Service.

Fire-fighting measures

Suitable extinguishing media : Carbon dioxide (CO2, Dry chemical, Sand
Unsuitable extinguishing media: : Water; Foam

Specific hazards during firefighting: Do not allow run-off from fire fighting to enter drains or water
courses. Burning produces noxious and toxic fumes.

Advice for firefighters

Special protective equipment for firefighters: In the event of fire, wear self-contained breathing apparatus. Full protective flameproof clothing

Further information : Collect contaminated fire extinguishing water separately. This must not be discharged into drains.Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. For safety reasons in case of fire, cans should be stored separately in closed containments.

Accidental release measures

Personal precautions : Use personal protective equipment.
Ensure adequate ventilation.
Remove all sources of ignition.
Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive
concentrations. Vapours can accumulate in low areas.

Environmental precautions : Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods for cleaning up : Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth,
vermiculite) and place in container for disposal according to local / national regulations.
Do not flush with water.

Handling and storage

Advice on safe handling :
For personal protection see above
Smoking, eating and drinking should be prohibited in the application area.
Take precautionary measures against static discharges.

Container may be opened only under exhaust ventilation hood.
To avoid spills during handling keep bottle on a metal tray.

Advice on protection against fire and explosion
Avoid formation of aerosol.
Keep away from sources of ignition - No smoking.
Take measures to prevent the build up of electrostatic charge.
Reacts violently with water, liberating highly flammable gases.
Will ignite if exposed to intensive heat or open air.

Conditions for safe storage, including any incompatibilities

Requirements for storage areas and containers:
Keep containers tightly closed in a dry, cool and well ventilated place.
Keep away from fire, sparks and heated surfaces.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Electrical installations / working materials must comply with the technological safety standards.

Advice on common storage : Never allow product to get in contact with water during storage.

Other data : No decomposition if stored and applied as directed.

-

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3394
Shipping information
Proper shipping name and description:
ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER-REACTIVE (Diisobutylaluminiumcyclohexylamine, Hexanes)
Chemical name:
ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER-REACTIVE (Diisobutylaluminiumcyclohexylamine, Hexanes)
Language:
English
Labels:
Labels : 4.2 (4.3)
Special provisions / remarks
Special provisions:
Hazard identification No : X333

Tunnel restriction code : (B/E)

Inland waterway transport (UN RTDG/ADN(R))

UN number:
3394
Shipping information
Proper shipping name and description:
ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER-REACTIVE (Diisobutylaluminiumcyclohexylamine, Hexanes)
Chemical name:
ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER-REACTIVE (Diisobutylaluminiumcyclohexylamine, Hexanes)
Language:
English
Labels:
Labels : 4.2 (4.3)
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3394
Shipping information
Proper shipping name and description:
ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER-REACTIVE (Diisobutylaluminiumcyclohexylamine, Hexanes)
Chemical name:
ORGANOMETALLIC SUBSTANCE, LIQUID, PYROPHORIC, WATER-REACTIVE (Diisobutylaluminiumcyclohexylamine, Hexanes)
Labels:
4.2 (4.3)
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not permitted for transport
Shipping information
Proper shipping name and description:
Not permitted for transport
Chemical name:
Not permitted for transport
Labels:
Not permitted for transport
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering measures
Use only in an area equipped with explosion proof exhaust ventilation.
Ensure that eyewash stations and safety showers are close to the workstation location.

Personal protective equipment
Respiratory protection : In the case of vapour formation use a respirator with an
approved filter.

Hand protection : Solvent-resistant gloves
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Before removing gloves clean them with soap and water.

Eye protection : Eye wash bottle with pure water
Tightly fitting safety goggles
Wear face-shield and protective suit for abnormal processing problems.

Skin and body protection : impervious clothing
Choose body protection according to the amount and concentration of the dangerous substance at the work place.

Hygiene measures : Handle in accordance with good industrial hygiene and safety
practice.
Wash hands before breaks and at the end of workday.

Environmental exposure controls
General advice : Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform respective authorities.

Stability and reactivity

Reactivity
Risk of violent reaction.

Chemical stability
No decomposition if stored and applied as directed.

Possibility of hazardous reactions
Hazardous reactions : Spontaneously flammable in air.
Reacts violently with water, liberating highly flammable gases.


Conditions to avoid : Heat, flames and sparks.

Contamination: Exposure to air, Exposure to moisture.

Incompatible materials
Materials to avoid : Water
Strong oxidizing agents
Strong acids and strong bases
Oxygen

Hazardous decomposition products: Carbon oxides, metal oxides

Disposal considerations

Waste treatment methods:
The product should not be allowed to enter drains, water courses or the soil.
Do not contaminate ponds, waterways or ditches with chemical or used container.
Offer surplus and non-recyclable solutions to a licensed disposal company.
Dispose of as special waste in compliance with local and national regulations.
Dispose of wastes in an approved waste disposal facility.

Contaminated packaging :
Empty remaining contents.
Dispose of as unused product.
Do not burn, or use a cutting torch on, the empty drum.