Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of necessary first-aid measures:
General information:
Pay attention to self-protection.
Remove victims from hazardous area.
Immediately remove soiled or soaked clothing and remove it to a safe distance.
Keep victim warm, in a stabilized position and covered.
Do not leave the victim unattended.
Place patients who are unconscious but breathing in the stabilized lateral position.

Inhalation:
Inhalation is possible if aerosols, mists, dusts, or smoke form.
Move to fresh air.
With labored breathing: Provide with oxygen.
Consult a doctor immediately.
If the casualty is not breathing: Perform mouth-tomouth resuscitation, notify emergency physician immediately.

Skin Contact:
Wash off affected area immediately with plenty of water for at least 15 minutes.
Get medical attention if any discomfort continues.

Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:
Rinse mouth.
Immediately give large quantities of water to drink.
Seek medical advice.

Personal Protection for Firstaid Responders:
No data available.

Most important symptoms and effects, both acute and delayed:
Symptoms:
None known.

Hazards:
Other dangerous properties can not be excluded.
Indication of immediate medical attention and special treatment needed Treatment:
This substance has no remarkable acute health hazard potential.
Acute health damage is therefore not to be expected.

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media:
All extinguishing substances suitable.

Unsuitable extinguishing media:
Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:
Danger of decomposition under influence of heat.

Hazard-determining flue gases might develop in case of fire:
- Carbon Monoxide
- Carbon dioxide
- Nitrogen Oxides

Advice for firefighters:
Special fire fighting procedures:
Take precautionary measures against static discharges.
Use water spray to cool unopened containers.
In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.
Fire residues should be disposed of in accordance with the regulations.
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.
Keep unauthorized personnel away.

Special protective equipment for fire-fighters:
In the event of fire, wear self-contained breathing apparatus.
Full protective suit.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Keep unauthorized personnel away.
For non-emergency personnel:
No data available.
For emergency responders:
No data available.

Environmental Precautions:
Observe regulations on prevention of water pollution (check, dam up, cover up).
Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:
Pick up mechanically and collect in a suitable container.
Avoid formation of dust.
To absorb spilled substance an approved industrial vacuum cleaner is recommended.
If necessary, the spilled substance should be moistened.
Pack and label wastes like the pure substance.
Do not detach label from the delivery containers prior to disposal.
Keep in suitable, closed containers for disposal.
Disposal according to local authority regulations.

Handling and storage

Precautions for safe handling:
Technical measures (e.g. Local and general ventilation):
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.
Decant and handle product in separate areas only, e.g. use glove boxes, cabinets with differential pressure switch etc.
Do not add wastewater to a biological wastewater treatment plant.In case of dissolved solids: Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
Ensure that dusthandling systems (such as exhaust ducts, dust collectors, vessels, and processing equipment) are designed in a manner to prevent the escape of dust into the work area (i.e., there is no leakage from the equipment).
All precautionary measures indicated have to be observed.

Safe handling advice:
Decant and handle product in separate areas only, e.g. use glove boxes, cabinets with differential pressure switch etc.
Ensure that apparatus and pipelines are free from leaks.
Do not ventilate into the open.
Dedicated loading/unloading stations required.
Risk assessment and risk monitoring of all work places required.
All precautionary measures indicated have to be observed.
Health, Safety and Emergency Management System recommended.
Regular safety training is a must.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities.
The personal protective equipment used must meet the requirements of Regulation (EU) 2016/425 and amendments (CE certification).
Handle in accordance with good industrial hygiene and safety practice.

Contact avoidance measures:
No data available.

Conditions for safe storage, including any incompatibilities Safe storage conditions:
Store in the original receptable, keeping this tightly sealed, under cool and dry conditions.
Protect from sunlight, warmth and heat.
In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.
In the event of internal transportation, already-opened containers are to be kept closed in order to avoid spillage.Normal measures for preventive fire protection.
Take precautionary measures against static discharges.
Further information: VDI 2263 "Dust fires and dust explosions; dangers, evaluation, preventive measures."
Ensure there are sufficient retaining facilities for water used to extinguish fire.

Safe packaging materials:
No data available.

Storage Class:
11: Combustible solids.

Transport information

Land transport (UN RTDG/ADR/RID)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Additional transport information

Additional information
Special provisions / remarks / other:
Combination traffic:
Labelling of containers / shipping units following main product run as per sea or air transport regulations.

Exposure controls / personal protection

Exposure controls:
Appropriate Engineering Controls:
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.
Decant and handle product in separate areas only, e.g. use glove boxes, cabinets with differential pressure switch etc.
Do not add wastewater to a biological wastewater treatment plant In case of dissolved solids:
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
Ensure that dusthandling systems (such as exhaust ducts, dust collectors, vessels, and processing equipment) are designed in a manner to prevent the escape of dust into the work area (i.e., there is no leakage from the equipment).
All precautionary measures indicated have to be observed.

Individual protection measures, such as personal protective equipment:
Eye/face protection:
Safety glasses with side-shields conforming to EN166 Accidental release measures close-fitting protective goggles (e.g. closed goggles).

Hand Protection:
Material: Nitrile.
Glove thickness: 0.11 mm
Guideline: DIN EN 374.
Material: Nitrile/Chloroprene
Glove thickness: 0.65 mm
Guideline: DIN EN 374.
Additional Information: Accidental release measures
Additional Information: Selection of protective gloves to meet the requirements of specific workplaces.
The suitability for a specific workplace should be discussed with the producers of the protective gloves.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside influences (e.g. temperature).

Skin and Body Protection:
Suitable protective clothing - Use disposable clothing if appropriate.

Respiratory Protection:
Accidental release measures: use respiratory equipment with suitable filter (filter type P3) or wear a self contained respiratory apparatus.
Note time limit for wearing respiratory protective equipment.

Hygiene measures:
Do not eat, drink, smoke, or sniff while at work.
Wash your hands and/or face before breaks and before termination of work.
Avoid contact with skin and eyes.
Implement skin protection measures according to skin protection schedule.
Take off contaminated clothing and wash it before reuse.

Environmental Controls:
In some cases, exhaust air scrubbers, filters or technical changes to the processing plant will be required in order to decrease emissions to acceptable values. 

Stability and reactivity

Reactivity:
No data available.

Chemical Stability:
Stable under recommended storage conditions.

Possibility of hazardous reactions:
No hazardous reactions are known if properly handled and stored.

Conditions to avoid:
- Sun rays
- Heat
- Heat effect

Incompatible Materials:
Strong acids.

Hazardous Decomposition Products:
- Carbon Monoxide
- Carbon Dioxide
- Nitrogen Oxides.

Disposal considerations

Waste treatment methods:
General information:
No data available.

Disposal methods:
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.
Strictly controlled conditions during disposal or treatment to air, wastewater and waste.
Do not add wastewater to a biological wastewater treatment plant Bring wastewater containing AOX for professional disposal.
Bring used exhaust air filter for incineration Disposal according to local authority regulations.

Contaminated Packaging:
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.