Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 November 2009 to 4 December 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
5-amino-3-methylthiophene-2,4-dicarbonitrile
EC Number:
610-868-8
Cas Number:
52603-48-2
Molecular formula:
C7N3H5S
IUPAC Name:
5-amino-3-methylthiophene-2,4-dicarbonitrile

Study design

Contact with:
other: not applicable

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information) negative
Parameter:
other: negative
Remarks on result:
other: result not specified (migrated information)
Remarks:
There were no groups present in the structure that would imply oxidising properties.
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information) negative
Parameter:
other: negative
Remarks on result:
other: result not specified (migrated information)
Remarks:
There were no groups present in the structure that would imply oxidising properties.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
Based on the chemical structure the result for the oxidising properties has been predicted negative.
Executive summary:

In a physico-chemical properties study (0656/0410), the substance has been predicted to not possess oxidising properties as there were no groups present in the structure that would imply oxidising potential based on Method A17 of Commission Regulation (EC) No 440/2008.