Endpoint:
oxidising solids
Type of information:
other: Expert statement
Adequacy of study:
supporting study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Expert statement following no specific guideline and without detailed description of results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Expert statement.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
4-piperidinecarboxylic acid hydrochloride
EC Number:
611-901-9
Cas Number:
5984-56-5
Molecular formula:
C6H11NO2.HCl
IUPAC Name:
4-piperidinecarboxylic acid hydrochloride
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study reports): JNJ-150098-AAC (T001310)
- Physical state: solid
- Appearance white powder
Specific details on test material used for the study:
- Batch n°: I14KB4913
- Analytical purity: 97.4% (base titration)
- Expiration date: 23 November 2020 (retest date)
- Storage condition: at room temperature

Results and discussion

Test results (Oxidising solids)
Sample tested:
other: Expert statement
Remarks on result:
not measured/tested
Remarks:
Result based on a theoretical expert statement

Any other information on results incl. tables

The test item does contain groups that act as oxidising agent. The oxygen atoms that are present in the molecular structure of the test item are chemically bonded to carbon or hydrogen. The test item also contains hydrochloric acid, which has no oxidising properties. The molecular structures of impurities were not taken into account. In conclusion, JNJ-150098-AAC (T001310) does not have oxidising properties.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Remarks:
Not oxidising
Conclusions:
It is concluded that the test item JNJ-150098-AAC (T001310) has no oxidising properties.