Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures:
Take off contaminated clothing immediately.
Pay attention to self-protection.
Move out of dangerous area.
Keep warm, position comfortably, and cover well.
Do not leave affected persons unattended.

Inhalation:
Remove to fresh air.
If feeling unwell seek medical advice.
Place patients at risk of losing consciousness in stabilized lateral position; artificial respiration as required
Monitor breathing, seek medical advice immediately.

Skin contact:
Wash skin thoroughly with soap and water or use recognized skin cleanser.
Consult a doctor in the event of permanent skin irritation.

Eye contact:
Rinse thoroughly with plenty of water, also under the eyelids.
See an eye specialist immediately.

Ingestion:
Do not induce vomiting and seek medical advice immediately.

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media:
foam
water spray
CO2
dry powder
Unsuitable extinguishing media:
High volume water jet

Special hazards arising from the substance or mixture:
May be released in case of fire: carbon monoxide, carbon dioxide, organic products of decomposition.
Under certain fire conditions, traces of other toxic products may occur.
Cool closed containers exposed to fire with water spray.
Closed container may rupture if strongly heated.

Advice for firefighters:
Also keep emptied containers away from sources of heat and ignition.
Containers exposed to heat (fire) may build up pressure. Cool by splashing with water.
Water for fire fighting must not be introduced in the sewer system, subsoil, or surface waters. Assure that there are sufficient fire water retaining facilities Contaminated fire fighting water must be disposed of in conformity with the regulations of the local authorities.
Have ready/wear respiratory protection equipment.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Wear personal protective equipment.
Do not breathe vapours or spray mist.
Ensure adequate ventilation.
Keep away from sources of ignition - No smoking.

Environmental precautions:
Do not flush into surface water or sanitary sewer system.

Methods and material for containment and cleaning up:
Take up mechanically or with an absorbent material.
Fill into marked, sealable containers.
To be disposed of in compliance with existing regulations.
Suitable binder:
sand, diatomaceous earth, universal absorbent
Additional advice
Assure sufficient ventilation.Vapours may form explosive mixtures with air.

Handling and storage

Precautions for safe handling:
Provide good ventilation or extraction.
Avoid contact with skin, eyes and clothing.
All metal parts of the mixing and processing equipment must be earthed.
Do not empty into drains.
Do not breathe in vapours, aerosols, sprays.
Wash hands before breaks and at the end of workday.
Remove contaminated or saturated clothing.

Conditions for safe storage, including any incompatibilities:
Advice on protection against fire and explosion
Take precautionary measures against static discharges.
Keep away from sources of ignition - No smoking.

Storage:
Keep containers tightly closed in a dry, cool and well-ventilated place.
Protect from the action of light.
Protect from moisture.
Advice on common storage
Observe prohibition against storing together!
Storage stability
Stable under recommended storage conditions.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls
Engineering measures:
Provide good ventilation or extraction.
Exposure controls
Provision of process technologies and monitoring in case of an accident or for waste treatment. Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.

Personal protective equipment:
Respiratory protection
In case of dusts/vapours/aerosols being formed or if the limit values like TLV are exceeded: Respirator with brown A-type filter or wear a self contained respiratory apparatus Note time limit for wearing respiratory protective equipment.

Hand protection:
The following details refer to information provided by Kächele-Cama Latex GmbH, Am Kreuzacker 9, D-36124 Eichenzell, www.kcl.de, which supplies the corresponding protective gloves.
Glove material nitrile rubber (Camatril Velours)
Material thickness 0,4 mm
Break through time > 480 min
Method DIN EN 374

Eye protection:
Safety glasses with side-shields

Hygiene measures:
Do not eat, drink or smoke while working. Wash hands, and/or face before breaks and when workday is finished. Avoid clothing from being contaminated with the product. Wash contaminated clothing after use. Apply adequate skin protection agents before handling the product. Assure skin cleaning and skin care after work. Preventive skin protection is recommended.

Stability and reactivity

Reactivity:
Under normal conditions: stable.

Chemical stability:
Stable under recommended storage conditions.

Possibility of hazardous reactions:
Possibility of hazardous reactions
No dangerous reaction known under conditions of normal use.

Conditions to avoid:
Keep away from heat and sources of ignition.

Incompatible materials:
Acids, Bases, Oxidizing agents

Hazardous decomposition products:
Decomposition products in combustion and thermal decomposition
carbon monoxide, carbon dioxide organic products of decomposition Phosphorus compounds

Disposal considerations

Waste treatment methods:

With respect to local regulations, e.g. dispose of to suitable waste incineration plant.
No waste key number as per the European Waste Types List can be assigned to this product, since such classification is based on the (as yet undetermined) use to which the product is put by the consumer.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.