Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18-Sep-2017 to 02-Oct-2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Batch: CVR 83297
Purity/Composition: 97.2%
Test item storage: At room temperature protected from light
Stable under storage conditions until: 27 December 2018 (expiry date)
Key result
Flash point:
116 °C
Atm. press.:
ca. 101 325 Pa

Test

Flash-point [°C]

Lowest flash-point [°C]

1

116

116

2

118

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol.
The flash-point of the test item was 116 °C.
Executive summary:

The closed cup method was applied for the determination of the flash-point of Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol in accordance with ASTM D 93. The flash-point of the test item was 116 °C.

Description of key information

The closed cup method was applied for the determination of the flash-point of Epoxypropyl neodecanoate, oligomeric reaction products with cyclohexane-1,2-dicarboxylic anhydride and propylidenetrimethanol in accordance with ASTM D 93. The flash-point of the test item was 116 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
116 °C

Additional information