Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove victim to fresh air. If cough or other respiratory
symptoms develop seek medical attention immediately. If not
breathing, give artificial respiration.
Emergency measure - Eyes: Immediately flush with copious amounts of water for at least
15 minutes. If irritation persists seek medical attention.
Emergency measure - Skin: Wash materials off the skin with soap and water. If
irritation persists seek medical attention.
Emergency measure - Ingestion: Seek medical attention immediately

Fire-fighting measures

Recommended extinguishing agent: Water fog, foam, dry chemical and carbon dioxide.

Product arising from burning: The substance is combustible and will burn if involved in a
fire, evolving noxious fumes (eg oxides of carbon). However,
there is no experimental evidence to support the
anticipated combustion products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards as
mentioned in section 2.3.10.


Absorb spillages with a suitable inert material (eg sand or
soil). Carefully transfer the spillage to waste
containers, or use a sealed industrial vacuum machine.
Containers filled with waste material must be labelled in
the same way as the original containers.


Clean the spillage area with water and detergent.


Dispose of waste material by incineration or landfill in
accordance with local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.


Engineering controls are necessary to reduce exposure to the
substance.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.
Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166


When necessary appropriate respiratory protection should be
used. e.g. an organic vapour mask conforming to EN405 FFA1.



The standards mentioned above should be regarded as a
minimum.

Storage: Store in a cool, dry, well-ventilated area.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 20 kg steel can

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: No specific recommendations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported

Chemical reaction with water: None reported

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration or landfill. In principle, it
may be possible to recover larger spillages of
uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: Not known.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with
inert material (eg sand or soil) may be disposed of by
landfill at an authorised tip in accordance with local
regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg oxides of
carbon and sodium-containing compounds) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: The substance should not be discharged directly to the
sewage system or the aqueous environment.