Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 Dec 2016 (experimental starting date) - 20 Feb 2017 (experimental completion date)
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
30 May 2008
Principles of method if other than guideline:
Anon (1989) Flash Point of Liquids by Setaflash Closed-Cup Apparatus, ASTM D-3278-89, P1-7
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method
Flash point apparatus:
Setaflash apparatus
Remarks:
Setaflash 30000-0 flash point tester
Flash point:
44.39 °C
Atm. press.:
99.6 kPa
Remarks on result:
other:
Remarks:
44.0 ± 2 °C
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash point of the test item has been determined to be 44.0 ± 2 °C.
Executive summary:

The flash point of the test item has been determined to be 44.0 ± 2 °C.

Description of key information

The flash point of the test item has been determined to be 44.0 ± 2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
44.39 °C

Additional information