Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

Toxicité aigüe par voie orale :

Une étude fiable (R2 selon l’échelle de Klimisch, 1997) (Carpenter et al., 1974) conduite sur des rats exposés à de l’acétylacétonate de chrome par voie orale (gavage) indique une dose létale médiane (DL50) de 3360 mg/kg de poids corporel, démontrant l’innocuité de la substance à enregistrer par cette voie d’exposition.

 

Toxicité aigüe par inhalation :

Une dérogation à l'obligation d'essais de toxicité aigüe par inhalation de la substance à enregistrer est invoquée selon l'annexe VIII du règlement REACH section 8.5.2., compte-tenu du fait que l'exposition des êtres humains est peu probable, la pression de vapeur de la substance à enregistrer étant considérée comme très faible (voir section 4.6 de ce dossier pour plus de détails sur la pression de vapeur de la substance à enregistrer). La substance à enregistrer est considérée comme n’ayant pas d’effet nocifs par cette voie d’exposition.

 

Toxicité aigüe par voie cutanée :

Une étude fiable (R2 selon l’échelle de Klimisch, 1997) (Carpenter et al., 1974) conduite sur des souris exposés à de l’acétylacétonate de chrome par voie cutanée indique une dose létale médiane (DL50) de 6350 mg/kg de poids corporel, démontrant l’innocuité de la substance à enregistrer par cette voie d’exposition.

 

 

Références :

 

Carpenter C, Weil CS, Smyth HF (1974) Range-Finding Toxicity Data: List VIII. Toxicology and Applied Pharmacology 28: 313-319.

 

Klimisch H-J, Andreae M, Tillmann U (1997). A systematic approach for evaluating the quality of experimental toxicological and ecotoxicological data.Regulatory Toxicology and Pharmacology 25:1-7.

Key value for chemical safety assessment

Acute toxicity: via oral route

Link to relevant study records
Reference
Endpoint:
acute toxicity: oral
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jusqu'à 1974
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 401 (Acute Oral Toxicity)
GLP compliance:
no
Test type:
standard acute method
Limit test:
no
Specific details on test material used for the study:
Aucun
Species:
rat
Strain:
not specified
Sex:
not specified
Details on test animals or test system and environmental conditions:
Aucun
Route of administration:
oral: gavage
Vehicle:
unchanged (no vehicle)
Details on oral exposure:
Non disponible
Doses:
Non disponible
No. of animals per sex per dose:
Non disponible
Control animals:
not specified
Details on study design:
Non disponible
Statistics:
Non disponible
Preliminary study:
Pas applicable
Key result
Sex:
not specified
Dose descriptor:
LD50
Effect level:
3 360 mg/kg bw
Based on:
test mat.
Mortality:
Non disponible
Clinical signs:
Non communiqué
Body weight:
Non communiqué
Gross pathology:
Non communiqué
Other findings:
Aucun
Interpretation of results:
other: Substance non classifiée
Conclusions:
La substance à enregistrer (Acétylacétonate de chrome) n'apparait pas comme nocive (DL50 comprise supérieure à 2000 mg/kg de poids corporel) pour les rats dans les conditions de test utilisées.
Executive summary:

L'acétylacétonate de chrome a été administré à des groupes de rats par voie orale. Une DL50 de 3360 mg/kg de poids corporel a été établie pour l'acétylacétonate de chrome.

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed
Dose descriptor:
LD50
Value:
3 360 mg/kg bw
Quality of whole database:
Ces données sont tirée d'une référence fiable (Klimisch 2): publication dans un journal à comité de lecture

Acute toxicity: via inhalation route

Link to relevant study records
Reference
Endpoint:
acute toxicity: inhalation
Data waiving:
other justification
Justification for data waiving:
the study does not need to be conducted because exposure of humans via inhalation is not likely taking into account the vapour pressure of the substance and/or the possibility of exposure to aerosols, particles or droplets of an inhalable size
Endpoint conclusion
Endpoint conclusion:
no adverse effect observed
Quality of whole database:
Une dérogation à l'obligation d'essai est invoquée pour cet effet.

Acute toxicity: via dermal route

Link to relevant study records
Reference
Endpoint:
acute toxicity: dermal
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jusqu'à 1974
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 402 (Acute Dermal Toxicity)
GLP compliance:
no
Test type:
standard acute method
Limit test:
no
Specific details on test material used for the study:
Aucun
Species:
mouse
Strain:
not specified
Sex:
not specified
Details on test animals or test system and environmental conditions:
Non disponible
Type of coverage:
not specified
Vehicle:
unchanged (no vehicle)
Details on dermal exposure:
Non disponible
Duration of exposure:
24 h
Doses:
Non disponible
No. of animals per sex per dose:
Non disponible
Control animals:
not specified
Details on study design:
Non disponible
Statistics:
Non disponible
Preliminary study:
Pas applicable
Key result
Sex:
not specified
Dose descriptor:
LD50
Effect level:
6 350 mg/kg bw
Based on:
test mat.
Mortality:
Non disponible
Clinical signs:
Non disponible
Body weight:
Non disponible
Gross pathology:
Non disponible
Other findings:
Aucun
Interpretation of results:
other: Substance non classifiée
Conclusions:
La substance à enregistrer (Acétylacétonate de chrome) n'apparait pas comme nocive (DL50 comprise supérieure à 2000 mg/kg de poids corporel) pour les souris dans les conditions de test utilisées.
Executive summary:

L'acétylacétonate de chrome a été administré à des groupes de souris par voie cutanée. Une DL50 de 6350 mg/kg de poids corporel a été établie pour l'acétylacétonate de chrome.

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed
Dose descriptor:
LD50
Value:
6 350 mg/kg bw
Quality of whole database:
Ces données sont tirée d'une référence fiable (Klimisch 2): publication dans un journal à comité de lecture.

Additional information

Justification for classification or non-classification

Toxicité par voie orale :

Sur la base de l'évaluation susmentionnée de la toxicité aiguë par voie orale de l’acétylacétonatede chrome, la valeur de DL50 provenant d’une étude fiable est supérieure à 2 000 mg/kg de poids corporel. En conséquence, l’acétylacétonate de chrome n’est pas classifié conformément à la directive 2001/59 / CE de la Commission (directive 67/548 / CEE) et conformément au CLP (règlement (CE) n ° 1272/2008 du Parlement européen et du Conseil) en tant que mise en œuvre du système UN-GHS dans l'Union Européenne.

 

Toxicité par voie cutanée:

Sur la base de l'évaluation susmentionnée de la toxicité aiguë par voie cutanée de l’acétylacétonate de chrome,la valeur de DL50 provenant d’une étude fiable est supérieure à 2 000 mg/kg de poids corporel. En conséquence, l’acétylacétonate de chrome n’est pas classifié conformément à la directive 2001/59 / CE de la Commission (directive 67/548 / CEE) et conformément au CLP (règlement (CE) n ° 1272/2008 du Parlement européen et du Conseil) en tant que mise en œuvre du système UN-GHS dans l'Union Européenne.

 

Toxicité par inhalation:

Sur la base de l'évaluation susmentionnée de la toxicité aiguë par inhalation de la substance à enregistrer, l’acétylacétonate de chromeest considérée comme n’ayant pas d’effet nocifs par cette voie d’exposition.En conséquence, l’acétylacétonate de chrome n’est pas classifié conformément à la directive 2001/59 / CE de la Commission (directive 67/548 / CEE) et conformément au CLP (règlement (CE) n ° 1272/2008 du Parlement européen et du Conseil) en tant que mise en œuvre du système UN-GHS dans l'Union Européenne.