Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05/08/2015 - 05/08/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Diarsenic triselenide
EC Number:
215-119-5
EC Name:
Diarsenic triselenide
Cas Number:
1303-36-2
Molecular formula:
As2Se3
IUPAC Name:
diarsenic triselenide
Test material form:
solid
Specific details on test material used for the study:
- Batch/lot nr: B200303
- Description: black crushed solid to powder
- Purity: 100%
- Manufacture date: June 2015
- Expiry date: 30 June 2035
- Storage conditions: Contolled room temperature (15-25°C, < 70% RH)

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
not determinable
Remarks:
the test item could not ignote, but melted.

Any other information on results incl. tables

  1. In the preliminary test the test item could not ignited, but melted. Based on the results of the preliminary test, no main test was performed.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In the preliminary test the test item could not ignited, but melted. Based on the results of the preliminary test, no main test was performed.
The test item considered flammable if the main test take less than 45 seconds. The test item could not ignited. Therefore, the substance is considered not to be highly flammable.
2 parallel flammability tests were performed. The tests were negative. The test item is not highly flammable in the conditions of this test.