Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 421-320-0 | CAS number: 118289-55-7 CP-89,575
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 5 March - 18 June 1996
- Reliability:
- 1 (reliable without restriction)
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 996
- Report date:
- 1996
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- other: EC Directive 92/69/EEC, Method A8 (shake-flask method)
- Principles of method if other than guideline:
- Test temperature: 20°C ± 0.5°C
Test I: octanol stock solution ( 10 ml) and water saturated with octanol (50 ml) were combined in a screw-capped glass jar. The jar was mechanically shaken for 15 minutes and the test phases separated by centrifuging at 2800 rpm for 15 minutes. The test was performed in duplicate.
Test 2: as for test 1 except that octanol stock solution (20 ml) was used. Test 3: as for test 1 except that octanol stock solution (40 ml) was used.
Blank test: as for test 2 except that water saturated octanol was used in place of the octanol stock solution. - GLP compliance:
- yes
- Type of method:
- shake-flask method to: flask method
- Partition coefficient type:
- octanol-water
Test material
- Reference substance name:
- 6-chloro-5-(2-chloroethyl)-1,3-dihydroindol-2-one
- EC Number:
- 421-320-0
- EC Name:
- 6-chloro-5-(2-chloroethyl)-1,3-dihydroindol-2-one
- Cas Number:
- 118289-55-7
- Molecular formula:
- Hill formula: C10 H9 Cl2 N O CAS formula: C10 H9 Cl2 N O
- IUPAC Name:
- 6-chloro-5-(2-chloroethyl)-2,3-dihydro-1H-indol-2-one
- Test material form:
- solid: particulate/powder
- Remarks:
- migrated information: powder
- Details on test material:
- Intended use: Pharmaceutical intermediate
Storage conditions: Dark at 4°C
Date received:2 February 1996
Constituent 1
Study design
- Analytical method:
- high-performance liquid chromatography
Results and discussion
Partition coefficient
- Type:
- log Pow
- Partition coefficient:
- 2.93
- Temp.:
- 20 °C
- Remarks on result:
- other: No Ph Data was available
- Details on results:
- The concentration of test substance in the octanol stock solution was determined as 1049.2 J..lg/ml (mean of individual determinations 1049.4 and 1048.9 J.lg/ml). The concentration of test substance based on mass oftest substance used was 1037.5 J..lg/ml.
CONCENTRATION AND TOTAL MASS OF TEST SUBSTANCE IN AQUEOUS AND ORGANIC TEST PHASES AFTER PARTITION
The aqueous phase concentrations ranged from 1.1142 - 1.3057 J..lg/ml, with pH values of 6.80 - 7.21. The organic phase concentrations ranged from 1011.8- 1040.5 J..lg/ml.
Quality control data for the aqueous phase analysis are given in Table 10, giving recoveries of 96.9% and 97.6%.
No peaks were observed at the retention volume of the test substance in any of the blank solutions indicating that the analytical method was free from interferences
Applicant's summary and conclusion
- Conclusions:
- The partition coefficient (n-octanol/water) of CP-89,575 has been determined as:
Log P = 2.93 at 20°C
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.