Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
Name of test material (as cited in study report): Carbonic acid, ethyl methyl ester
Analytical purity: not specified
Lot/batch No.: 10175-151

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
30 - 500 °C
Remarks on result:
other: 1st exothermic reaction: 10J/g at 165°C onset temperature; 2nd exothermic reaction: 370J/g at 400°C onset temperature

Any other information on results incl. tables

1st Reaction:

Onset temperature:       165°C

Peak temperature:        187°C

Energy release:             10J/g

2nd Reaction:              

Onset temperature:      400°C

Peak temperature:       439°C

Energy release:            370J/g